Battery Backup Use Case Classifier

Describe why you want a home battery and a text model in your browser matches it to a use case like outage backup or solar storage.

Nothing is uploaded.

Last updatedHow we build & check our tools

Interactive Tool

This tool runs in your browser and is loading now.

Enter your values once it appears to see your results.

How Battery Backup Use Case Classifier works

Press Load model once: your browser downloads Universal Sentence Encoder (MediaPipe) (13 MB) from this site and keeps it in its cache. Then add your text and press Classify locally. The model runs on this device, so nothing you enter is sent to a server. Until the model is loaded, or if your device cannot run it, the tool falls back to a simple keyword check and labels the result as the fallback.

Universal Sentence Encoder (MediaPipe) turns text into a list of numbers that captures its meaning, so two sentences about the same thing end up close together even when they share no words. Each label below comes with a handful of example phrases. The tool compares your text with every example and picks the label whose closest example is nearest in meaning.

Scores are the cosine similarity between your text and that closest example, rescaled to 0-100: this model rarely scores two English sentences below 0.6 even when they are unrelated, so 0.6 maps to 0 and an exact match to 100. When the top two labels are within 3 points the result says it is a close call, because the model is effectively unsure.

Labels and example phrases

  • Medical device backup - Size for the devices' wattage and run time; ask your utility about medical baseline programs and keep a separate plan. Examples: "need to keep my oxygen concentrator running during outages", "CPAP machine has to work when the power goes out", "home dialysis equipment needs reliable power".
  • Outage backup for essentials - Pick the circuits you must keep (fridge, internet, sump, furnace fan) and size for the longest outage you expect. Examples: "keep the fridge, internet and lights on during blackouts", "sump pump must run when storms knock the power out", "we lose power a few times every winter".
  • Bill savings with time-of-use rates - Compare peak and off-peak prices; savings depend on the spread and battery cycling. Examples: "charge the battery off-peak and use it from 4 to 9pm", "avoid peak electricity prices in the evening", "our utility moved us to a time-of-use plan".
  • Storing solar for later - Check your net metering or export rate; batteries pay off most when exports earn little. Examples: "store extra solar during the day for the evening", "net metering ended so exports are worth very little", "use more of our own solar power".
  • Off-grid or remote power - Size for days of autonomy and add a generator or more panels for cloudy stretches. Examples: "cabin with no grid connection", "off grid tiny house with solar panels", "power for a remote workshop far from the lines".

Worked example

The model's output for the built-in sample, recorded on a desktop browser. Your run may word things slightly differently.

Backup note: Need fridge, Wi-Fi, sump pump, and two medical devices during outages. Average outage 6 hours, occasional winter storm lasts 18 hours.
Best match
Medical device backup
Runner-up
Outage backup for essentials
How clear-cut
Leaning
All labels
Medical device backup 62 · Outage backup for essentials 59 · Bill savings with time-of-use rates 56 · Storing solar for later 50 · Off-grid or remote power 49

The model

The files are served from this site, versioned so a cached copy is never stale. Nothing is fetched from a third party while you use the tool.

You can switch models in the tool. Also available: Gemma 4 E2B instruction-tuned (web build) (2.0 GB). The larger language model gives more thorough answers but is a bigger download and needs a stronger device.

ModelDownloadRuns onLicence
Universal Sentence Encoder (MediaPipe)6.1 MBProcessor (WebAssembly)Apache-2.0
Gemma 4 E2B instruction-tuned (web build)2.0 GBGraphics card (WebGPU)Apache-2.0

Limitations

  • Similarity in meaning is not the same as a rule. A text about a topic can land on the label whose examples share that topic even when a person would pick another label, so read close calls yourself.
  • The labels are fixed. If your text belongs to none of them, the tool still picks the nearest one; a low top score is the hint.
  • Results describe the input you gave, not the real-world situation behind it. Review them yourself before acting.

Good uses

  • Triage energy and utilities notes before deeper review
  • Prepare consistent labels for repeat workflows
  • Reduce manual sorting on small batches
  • Keep sensitive drafts in the browser preview

Frequently Asked Questions

Common questions about the Battery Backup Use Case Classifier

No. The model files download from this site once, and then everything runs in your browser tab. The text you enter is never sent to a server, and closing the tab discards it.

Sources & References

International System of Units (SI): energy, work and heat

Energy, work and heat is measured in the joule (J); 1 cal = 4.184 J. Conversions between SI and other units use exact, internationally agreed factors maintained by NIST.

International System of Units (SI)

Authoritative definitions for energy, work and heat, from the BIPM SI Brochure (9th edition), the defining reference for the SI.

Explore More Tools

Explore these related tools for your next step.

energy

Multi-Zone Mini Split Sizing Calculator

Estimates the cooling load of up to five rooms, rounds each to a standard ductless head (9k, 12k, 18k or 24k BTU/h), and suggests a multi-zone outdoor unit. For homeowners comparing quotes before asking an installer for a Manual J.

Try it now
energy

Home Electrical Load & Service Size Calculator (NEC 220.82)

Applies the NEC 220.82 optional method to a single-family home to estimate service load in amps, pick the next standard service size, and show headroom for an EV charger or heat pump. For homeowners and contractors planning an upgrade.

Try it now
energy

Firewood Cord Calculator (Stack Size, Price & Heat Value)

Measures a firewood stack in cubic feet and cords, shows what you paid per full cord, and estimates heat content by species along with cost per million BTU. You can compare against your own electricity, propane and natural gas prices.

Try it now
energy

Server Rack Power & Cooling Calculator

Totals the power of every device in a rack, shows amps per phase, how many circuits the 80% continuous rule requires, heat in BTU/h and tons of cooling, and a yearly electricity cost with PUE applied. For IT staff and small server room owners.

Try it now
energy

Blower Door ACH50 & Natural Air Changes Calculator

Turns a blower door CFM50 reading into ACH50, estimates natural air changes per hour, compares ACH50 with the 2021 IECC limit for your climate zone, and gives the ASHRAE 62.2 total ventilation rate. For homeowners, energy auditors and builders.

Try it now
energy

Ceiling Fan Size Calculator

Recommends a blade span for your room size, an estimated downrod length for your ceiling height, ENERGY STAR airflow and efficiency targets, and the yearly running cost of the fan. For anyone choosing a ceiling fan.

Try it now